Tag Line
Custom-Hoists custom Hoists equipment
Custom Hoists Cylinder-Hoist
Green Bullet Home
Green Bullet Company Profile 
Green Bullet Technical Service
Green Bullet Products
Green Bullet Single-Acting Telescopic Cylinders
Green Bullet Double-Acting Telescopic Cylinders
Green Bullet Piston Rods
Green Bullet General Information
Green Bullet Specifications
Green Bullet Request Information
Green Bullet Contact Us
Green Bullet Distributor Finder
Green Bullet Warranty
Piston Rod Cylinder Product Information
 
Square Green Bullet Specifications

Rod Bore Diameter

2"

Cross Sectional Area

3.14 in2

1,800 (PSI)

5,672

2,000 (PSI)

6280

2,500

 (PSI)

7850

3,00 

(PSI)

9420
  
Square Green Bullet  Lifting Capacities 
Piston Rod Cylinders
  Specific Operating Pressures
Rod Bore
Diameter (in.)
Cross Sectional Area (Sq. In.)
1,800 PSI (lbs.)
2,000 PSI (lbs.)
2,500 PSI (lbs.)
3,000 PSI (lbs.)

2

3.14

5,672

6,280

7,850

9,420

2-1/2

4.90

8,820

9,800

12,250

14,700

3

7.06

12,708

14,120

17,650

21,180

3-1/2

9.62

17,316

19,240

24,050

28,860

4

12.56

22,608

25,120

31,400

37,680

4-1/2

15.90

28,620

31,800

39,750

47,700

5

19.63

35,334

39,260

49,075

58,890

5-1/2

23.75

42,750

47,500

59,375

71,250

6

28.27

50,886

56,540

70,675

84,810

6-1/2

33.18

59,724

66,360

82,950

99,540

7

38.48

69,264

76,960

96,200

115,440

7-1/2

44.17

79,506

88,340

110,425

132,510

8

50.26

90,468

100,520

125,650

150,780

8-1/4

53.50

96,300

107,000

133,750

160,500

8-1/2

56.74

102,132

113,480

141,850

170,220

9

63.61

114,498

127,220

159,025

190,830

9-1/2

71.00

127,800

142,000

177,250

213,000

9-3/4

74.50

134,100

149,000

186,250

223,500

10

78.54

141,372

157,080

196,350

235,620

10-1/2

86.59

155,862

173,180

216,475

259,770

 

Back to Top
 
 Square Green Bullet Model and Serial Number 

MN Double-Acting or Single-Acting (SA) Piston Rod Cylinder

 The following is an example of Custom Hoists, Inc. model numbers:

Piston Rod part numbers

Locator

Custom Hoists, Inc. model numbers and serial numbers are either stamped on the O.D. of the cylinder body (manufactured prior to 8-99) or stamped on a metal plate which is welded to the O.D. of the cylinder body (manufactured after 8-99). Using these model numbers will eliminate misunderstandings when placing orders or requesting information.

Model number and serial number stamped in body or on a name plate.

pn-locator

 
Back to Top
 
Square Green Bullet Safety Precautions  
WARNING!
Rollover or lateral tilt can cause severe injury or death and/or damage to the unit and cylinder.

  • The hydraulic cylinder will not prevent the unit from rollover or lateral tilt. The cylinder is strictly a lifting device and is not a structural member of the unit. Cylinders are not to be used as a means of stabilizing the unit.
  • The hydraulic cylinder mounted in the unit should be free to find its own trajectory line of extension and retraction so as not to cause improper sequencing and excessive wear to the plungers and internal components. Misalignment could cause the unit to upset. On longer stroke cylinders mounted horizontally, supports should be added to the center of the extended cylinder to increase the column strength of the cylinder.
  • The hydraulic cylinder will not withstand lateral pressure when the unit is leaning. Only activate the cylinder when the tractor and trailer are in a straight line (not jack-knifed). Do not activate the cylinder while on unlevel or soft ground, or during heavy crosswinds. Doing so may cause the unit to upset.
  • Do not activate the cylinder while personnel or equipment are alongside or behind the unit.
  • On roll-off units, if the container is not loaded evenly, the lift cylinder(s) may mis-stage which could cause the unit to upset and/or damage the cylinder when the plungers attempt to correct themselves.
  • On roll-off units, lower the container with the control valve partially open (avoid lowering the container with the control valve completely open) to prevent pressure build-up in the reeving cylinders as gravity pulls the container to the ground.

WARNING!
Shock pressure can cause severe injury or death and/or damage to the unit and cylinder.

  • Do not extend the cylinder until it has been fully retracted. A partially extended cylinder with pressure relieved may drift out of position. When the cylinder is later extended, the out of position plunger will reposition rapidly and possibly cause high pressure trapped oil on the retract side of the cylinder. On roll-off units, do not pull a container onto the hoist until the lift cylinder(s) are completely extended.
  • On roll-off units, care must be taken if a unit is moved with the lift cylinders extended. Avoid sudden stops or jolts.
  • Check the cylinder operation to ensure the plungers extend in sequence with the largest diameter plunger moving first, then the next largest, etc. When retracting, the smallest plunger should move first, then the next smallest, etc. Mis-staging could cause the unit to upset and/or damage the cylinder due to excessive pressure build-up.

WARNING!
Over pressurizing the cylinder can cause severe injury or death and/or damage to the unit and cylinder.

  • Do not operate the cylinder at pressures greater than 2000 P.S.I. unless otherwise approved in writing by Custom Hoists, Inc.
  • Hydraulic hoses should be checked regularly and replaced if worn out or damaged.

NOTICE!

Do not operate a packer/ejector cylinder with a mis-aligned blade. This can cause excessive lateral loading to the cylinder which could cause internal damage.

If the hydraulic system uses quick disconnects or holding/lock type valves, make sure they are properly connected. If not, oil may become trapped in the cylinder which could cause internal damage.

A double-acting telescopic cylinder normally requires at least 15 G.P.M. oil flow to retract properly. Make sure the hydraulic pump is developing the required flow.

Most double-acting telescopic cylinders will bleed themselves of air. On a new cylinder installation, cycle the cylinder approximately ten times to the complete extend and retract positions with no load against it to remove the entrapped air.

The hydraulic oil should be checked and changed regularly to avoid contamination leading to internal cylinder damage.

Grease the pin mountings regularly.
Back to Top